<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>sys</ParameterFamily>
<LongName>
chiller_installed
</LongName>
<Name>
chin
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Platesetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
<ListItem><TextApplies>ThermoFlex</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
For the 1.7x heads (and soon thermal 2) a liquid cooling system is required.  This parameter
informs the firmware if the unit should be present in the system configuration.  With this
parameter set to 0 a chiller is not expected and control signals will not be sent - even if
the cable is plugged in and the cable detected.  The chiller is required to prevent overheating
of the laser imaging head.
</text></DescriptionText>
<DescriptionText><text>
It is normal for the chiller's compressor to be turned on and off as the head requires when used
in conjunction with 1.7x heads.  Thermal 2 and TFX heads do not yet support (and may never) the
commands to do this so the chiller will simply be turned on (pump and compressor) all of the time
and left to self regulate.
</text></DescriptionText>
</Description>
<Type>
boolean
</Type>
<Default>
<UnnumberedList>
<li>1</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/head_cal_casehigh.xml</LinkAddress><LinkTitle>NVS: head casehigh</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/head_cal_caselow.xml</LinkAddress><LinkTitle>NVS: head caselow</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:41 2008 PST
</Updated>
<Links>
</Links>
</Parameter>